Sistem pemulihan panas iki bisa disambungake menyang pompa panas sistem banyu.Banyu ing pipa Penagih nyambungake ERV bisa preheated metu lawang mlebu online, nambah suhu udhara seger ngetik kamar lan nambah comfort saka lingkungan njero ruangan.
Aliran udara: 250 ~ 500m³ / h
Model: TFWC A1 seri
1. Pemurnian hawa seger + Recovery energi + Pemanasan lan pendinginan
2. Aliran udara: 250-500 m³ / jam
3. inti pertukaran entalpi
4. Filter: Layar utama G4 + layar Hepa12
5. Perawatan lawang sisih
6. Pemanasan PTC
7. Fungsi bypass
Panggonan pribadi
Distrik pemanasan pusat
Komersial
Hotel
Model | Dirating Airflow (m³/jam) | Rated ESP(Pa) | Temp.Eff. (%) | rame (dB(A)) | Efisiensi purifikasi | Volt.(V/Hz) | Input daya (W) | Kalori Pemanasan/pendingin (W)
| NW (Kg) | Ukuran (mm) | Formulir kontrol | Ukuran Sambungan |
TFWC-025 (A1-1D2) | 250 | 100(200) | 75-80 | 35 | 99% | 210-240/50 | 100(300*2) | 500~1500 | 58 | 1200*780*260 | Kontrol cerdas / APLIKASI | φ150 |
TFWC-035 (A1-1D2) | 350 | 100(200) | 75-80 | 37 | 210-240/50 | 130(300*2) | 500~1500 | 58 | 1200*780*260 | φ150 | ||
TFWC-500 (A1-1D2) | 500 | 100 | 75-80 | 40 | 210-240/50 | 220(300*2) | 500~1500 | 58 | 1200*780*260 | φ200 |
Filter G4+H12)*2 Udara seger sing luwih resik
Countercurrent cross enthalpy exchange inti, efficiency exchange panas luwih
Skema instalasi ERV kumparan banyu
1: Unit njaba AC pompa panas
2: Pemanasan lantai
3: Tangki banyu
4: pengontrol ERV
5: Pompa panas ERV
Lokasi instalasi mung kanggo referensi.Nindakake instalasi miturut diagram desain
Kepiye babagan efek pemanasan ERV kumparan banyu?
Ayo ndeleng sakumpulan data eksperimen
Preheating coil beban pitungan (inquire standar Yinchuan ing China nilai tekanan atmosfer: 88390pa) | |||||||
kacepetan angin | Suhu inlet Coil (℃) / Kelembapan relatif (%) | Entalpi inlet kumparan (KJ/KG) | Suhu inlet Coil (℃) / Kelembapan relatif (%) | Entalpi inlet kumparan (KJ/KG) | Aliran udara (m³ / h) | Kapadhetan hawa (kg/m³) | Beban preheating (W) |
dhuwur | 1.93/43.01 | 7.2 | 20.40/13.78 | 26.5 | 300 | 1.117 | 1797 |
agêng | 1.93/43.01 | 7.2 | 21.77/13.34 | 28.3 | 250 | 1.117 | 1637 |
kurang | 1.93/43.01 | 7.2 | 23.17/10.76 | 28.9 | 200 | 1.117 | 1347 |
1, test situs coil banyu inlet suhu: 32,3 ℃, suhu stopkontak: 22,1 ℃;
2. Miturut prabédan enthalpy saka inlet lan outlet online saka coil, beban panas saka coil diwilang.
3. Inquire Nilai tekanan atmosfer Yinchuan standar: 88390pa
Nalika kotamadya dadi panas banyu panas ora luwih murah tinimbang 30 ℃, kapasitas preheating saka telung pipa penggemar anyar (karo preheating coil) ing dhuwur / medium / kacepetan kurang:
Kacepetan dhuwur 1797W, kacepetan medium 1637W, kacepetan kurang 1347W
Ketemu syarat preheating saka hawa seger.
Motor DC: Efisiensi Energi lan Ekologi sing Luwih Dhuwur dening Motor Kuat
Inti pertukaran sing bisa dicuci:Membran sing dimodifikasi sing bisa ngumbah inti ijol-ijolan entalpi lan umure 3-10 taun
Teknologi ventilasi pemulihan energi: Efisiensi pemulihan panas bisa tekan luwih saka 70%
Kontrol sing luwih cerdas: APLIKASI + Pengontrol cerdas